Unilin FR/ALU Flat Roof Insulation (Xtratherm)
€42.09 – €128.60 (Inc. VAT)
Unilin (previously Xtratherm) Thin-R Flat Roof Insulation (FR/ALU)
Key features:
- High thermal performance PIR insulation board for flat roofs
- Features vapour-tight aluminium foil facings suitable for use with single ply membranes
- Compatible with mechanically fixed single ply systems/ Loose laid ballasted systems
- Insulation for Mechanically Fixed Single Ply Waterproofing Systems
- Range of thicknesses available
- Unilin was previously known as Xtratherm
Enter Eircode at checkout for delivery pricing.
Product Description
Unilin (previously Xtratherm) FR/ALU is a high performance PIR insulation for use on a flat roof. It features vapour-tight aluminium foil facings suitable for use with single ply membranes.
Key features:
- High thermal performance PIR insulation board for flat roofs
- Features vapour-tight aluminium foil facings suitable for use with single ply membranes
- Compatible with mechanically fixed single ply systems/ Loose laid ballasted systems
- Insulation for Mechanically Fixed Single Ply Waterproofing Systems
- Range of thicknesses available
Specification:
- 2400mm wide x 1200mm long
- Range of thicknesses available
- Density (Foam Core): 32 kg/m3
- Compressive Strength: >150kPa @ 10% Compression
- Thermal Conductivity: 0.022 W/mK
Unilin (previously Xtratherm) FR/ALU is faced with gas-tight foil. Xtratherm FR/ALU foil faced roof boards are suitable for use below single ply mechanically fixed roof membranes.
Note: FR/ALU is not suitable for applications with built-up bitumen based roofing or mastic asphalt systems.
Unilin (previously Xtratherm) FR/ALU insulation boards should be laid over the vapour control layer in a break bonded pattern. The long edges of the boards should be laid at right angles to the corrugations and all board joints must be fully supported by the deck. The FR/ALU insulation boards are secured by approved mechanical fixings.
The requirement for a separate water vapour control layer should be assessed in accordance with BS 6229. Typically a 1000 gauge polythene should be used
with all joints lapped and sealed. Any fixings that penetrate it must be of the self sealing type that fuses to the vapour control layer during application.
Unilin (previously Xtratherm) FR/ALU foil faced insulation boards are suitable for use on roof decks that are subject to maintenance traffic. Walk ways should be provided on roofs requiring regular pedestrian access. When the roof is complete, protective boarding should be laid if additional site work is to be carried out. The completed roof should not be used for storage of heavy materials or air conditioning plant.
Roof design:
Consideration should be given to the recommendations of BS 4841: Part 3 and those of the Single Ply Roofing Association.
Falls:
The fall on a flat roof should be constant and steep enough to ensure that rainfall does not pond.
Fire performance:
The fire rating when tested to EN 13501-5 and BS 476 Part 3 ‘External Fire Exposure Roof Test’ will be dependent upon waterproofing system specified
U Value information:
Unilin (previously Xtratherm) FR/ALU foil faced roof boards are suitable for use below single ply mechanically fixed roof membranes.
Note: FR/ALU is not suitable for applications with built-up bitumen based roofing or mastic asphalt systems.
Vapour Control Layer
The water vapour control layer should be laid with 150mm laps, which are turned up at any vertical upstand. When the insulation boards have been positioned the laps are turned over and sealed, prior to the roof finish being completed.
Laying (Metal/Timber Deck)
Unilin (previously Xtratherm) FR/ALU foil faced boards should be laid over the vapour control layer in a break bonded pattern. The long edges of the boards should be laid at right angles to the corrugations and all board joints must be fully supported by the deck. The FR/ALU insulation boards are generally secured by approved mechanical fixings.
Laying (Concrete Deck)
Unilin (previously Xtratherm) FR/ALU boards are laid over the vapour control layer in a break bonded pattern and secured with approved mechanical fixings, or secured under a ballasted system. Care should be taken to ensure that the concrete deck is graded to the correct falls, dry, clean and free from any
projections or gaps.
Fixing
The specification for fixing Unilin (previously Xtratherm) roof boards will vary with the location, roof height/area and topographical data. Architectural specification should be consulted. Generally with 2400mm x 1200mm boards, a minimum of 6 fixings are adequate, located between 50mm and 150mm from all edges, additional fixings may be placed along the centre line. Additional fixings around roof perimeter may be required. 11 fixings per 2400mm x 1200mm sheet is recommended. Counter sunk washers, 50mm in diameter should be used with each fixing.
However, BS 6399:Part 2 should always be consulted. During the construction process, the construction should be protected from rain penetration during breaks in the process.
What makes this different to Unilin (previously Xtratherm) Floor Insulation boards?
- Manufactured with slightly higher compressive strength – i.e it can withstand more loading
- Manufactured to tighter tolerances – for fixing the water proofing and/or air tight membranes etc
- There are less steps built into the surface of the insulation
Specification statement:
The flat roof insulation shall be Unilin (previously Xtratherm) Thin-R FR-ALU manufactured to EN 13165 by Xtratherm, comprising a rigid Polyisocyanurate (PIR) core between low emissivity foil facings. The FR-ALU_ _ _mm with a Agrément declared Lambda value of 0.022 W/mK to achieve a U value of __ _ _W/m2K for the roof element. To be installed in accordance with instructions issued by Xtratherm.
Information about the Xtratherm Thin-R range:
Unilin (previously Xtratherm) Thin-R range is a high performance foil faced Polyisocyanurate (PIR) insulation with a certified thermal conductivity as Low as 0.022 W/mK. Thin-R is also available with engineered jointing to provide improved continuity and thermal bridging performance.
Downloads:
Delivery charge information:
You can add any and all products to the basket and calculate your delivery charges easily. Simply enter your Eir Code and all applicable charges will be calculated automatically.
- Orders of €150 inc VAT or over will get free delivery nationwide. (Please see notes below for exceptions)
- All orders under €150 inc VAT incur a standard delivery charge of €10 including VAT
- (Please see below for exceptions)
- We deliver to anywhere in Ireland.
Bulky items:
Bulky items may incur delivery surcharges (see below) as extra courier costs unfortunately are often unavoidable. If the order is over €150 only the bulk delivery charge will apply. The final delivery charge for bulky products will be calculated when all items have been added to the shopping cart.
All efforts are made to indicate where products are subject to delivery surcharges.
Special Order items:
We are in regular contact with our suppliers and we try our best to make sure that all “special order items” on our webstore are available from our suppliers within the timeframe advertised. If, for some reason our supplier is out of stock and you have ordered the product we will let you know immediately and give you the option to either wait until it’s back in, upgrade to a better model at little or no extra cost or receive a full refund. See more info on Special Order products here.
Timeframe:
All nationwide deliveries will be delivered within 2-3 working days.
(Local deliveries within 1-2 working days.)
Special order items may take longer to deliver but this will be indicated on the product information page. You can see more info on Special Order products here.
Working days are Monday through Friday excluding public holidays. Orders placed on Saturday/Sunday will be deemed as being placed on the following Monday.
Some items may take longer to ship. If this is the case, we will notify you by phone/email of this delay.
If your delivery is urgent please contact us by phone or email and we will do our best to expedite it.
Please indicate on your order any specific delivery instructions.
Bulky goods:
Bulky goods will be delivered on pallets and will be unloaded by the courier. All bulky goods are delivered kerbside. Unfortunately, the delivery company will not convey the goods into premises for storage unless agreed in advance. Access to the delivery location must be suitable for a truck and failure to provide suitable level ground for operating pallet truck may result in refusal to deliver by the courier. Please note delivery operators will apply safe procedures in relation to ongoing Public Health considerations..
Exceptional Goods:
Some building materials are extremely bulky and not practical to deliver outside Co. Sligo e.g. concrete blocks, tonne bags of sand or gravel or some lengths of timber. We have highlighted where this is the case in bold red writing. If you do order these products we will contact you to see if you want to pay an additional delivery charge or if you wish to cancel the order. Please do not take offence to this as some bulky goods may cost much more to deliver than the value of the goods. We are based in Sligo so can offer a local delivery service in this area using our own vehicles.
If there is a forklift or teleporter available onsite, we would appreciate if you could tell us in advance by filling out the special delivery notes when completing the order.
The Seller or the courier company will not be held responsible for any damage to goods or persons caused by the goods being unloaded by the buyer.
**Please contact us in advance of ordering if unsure of the above**
Damaged goods:
Where goods are damaged on delivery the Buyer has the right to refuse delivery. Damaged goods should be photographed on delivery and photos emailed to sales@mybuildingsupplies.ie straight away. If goods are damaged on delivery, we will replace the goods in as timely a manner as possible at no extra cost.
Once the goods are signed for it will be deemed that goods were in good state when delivered.
General:
Delivery shall be within a time period agreed between the Buyer and Seller and the Seller shall use its best endeavours to ensure that delivery takes place within the period agreed. Failure by the Seller to deliver the Goods within the agreed time period shall not amount to a breach of this contract by the Seller and the Buyer shall not be entitled to damages or other compensation or to cancel this contact by reason of such failure.
The Seller reserves the right to deliver in instalments. Each part delivery shall be deemed to constitute a separate contract, the fulfilment or non-fulfilment of which shall not affect any other part of the contract or the contract as a whole. Where any order involves more than one delivery and default is made on payment on the due date (either under this contract or any other contract made between the Seller and the Buyer) the Seller shall have the right to suspend all further deliveries until payment is made or to terminate the contract without prejudice to any existing claim.
The Seller shall not be liable to the Buyer for any loss or damage which may be suffered by the Buyer as a direct or indirect result of the supply of the Goods by the Seller being prevented, hindered or delayed by reason of any circumstances whatsoever which are outside the control of the Seller. Once delivery has been accepted the Buyer shall not be entitled to withhold or postpone payment of all or any portion of the price agreed, therefore.
1. Where goods are damaged on delivery the Buyer has the right to refuse delivery. Damaged goods should be photographed on delivery and photos emailed to sales@mybuildingsupplies.ie. If goods are damaged on delivery, we will replace the goods in as timely a manner as possible at no extra cost.
2. If goods are signed for and later found to be faulty/damaged, notice must be given in writing within 24 hours and photos will be required to be emailed to sales@mybuildingsupplies.ie.
3. All faulty/damaged goods issues will be dealt with on a case by case basis and best endeavours will be made to rectify within a timely manner. Manufacturers’ warranties will apply in certain cases.
4. Any returned items which are not faulty or damaged will incur full carriage costs which must be paid for by the customer. Notice of intention to return unwanted goods must be given within 14 days of receiving goods. Returned goods must be in original packaging and in original condition before refunds can be given.
5. All returned goods to be sent to Patrick Rogers Ltd., O’Connell St., Ballymote, Co. Sligo
Note regarding Oil Boilers and Boiler stoves:
Please ensure you check with us first or consult a qualified professional before ordering your oil boiler or boiler stove to ensure you order the correct one for your home. If the product needs to be returned a restocking fee may apply.
Returns of Special Order Items
All “special order items” are subject to the same product returns policy as stocked items. However, items which are returned that are not faulty or damaged on delivery will be subject to a 10% restocking fee.
Reviews
There are no reviews yet.